[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Contact ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Subscription::
Contact us::
Site Facilities::
::
Search in website

Advanced Search
Receive site information
Enter your Email in the following box to receive the site news and information.
Last site contents
:: Editorial Board
:: About Iranian Journal of Endocrinology and Metabolism
:: Volume 12, Issue 1 (5-2010) ::
2010, 12(1): 65-70 Back to browse issues page
Microwave Digestion for Urine Iodine Determination
M Khazan , P Yaghmaei , L. Behdadfar , MS Daneshpour , M Hedayati
, hedayati@endocrine.ac.ir
Abstract:   (23574 Views)

Introduction: Digestion is an important step in urine iodine determination methods. High temperatures and long heating durations can be considered as weaknesses of the present methods. The aim of the study was assessment of microwave use for digestion of urine and decompostion of interfering substances, aimed at shortening the time and increasing safety in the procedure. Materials and Methods: Random urine samples were processed by conventional acid digestion and also by new microwave optimized digestion methods. After digestion, iodine levels of samples, digested by the two mentioned methods, were also determined using chemical colorimetric kinetic reaction Ce+4 and Ce+3 according to the well known Sandell-Kolthoff reaction. Microplate reading format by ELISA reader was used to increase speed and precision of reading. Sensitivity, precision and comparison results were assayed in both the methods as well. Results: Optimized microwave digestion showed that merely a 10 min duration is adequate for complete digestion of urine samples. Intra- and inter- assay coefficients of variation were 6.7- 9.3% and 9.8-12.3% respectively. The final results of the comparison of iodine contents of samples, were obtained through the two microwave and conventional methods, showed acceptable correlation (r=0.928). The assay recovery was 91-113% and the sensitivity 5 µg/dL. Conclusion: The results of this study showed that the microwave procedure for urine digestion is acceptable. The digestion method obtained comparable results with conventional digestion methods, and can hence replace conventional electrical heat digestion methods.

Keywords: Microwave, Acid digestion, Urine iodine
Full-Text [PDF 271 kb]   (4321 Downloads)    
Type of Study: Original | Subject: Biochemistry
Received: 2009/09/11 | Published: 2010/05/15
Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Khazan M, Yaghmaei P, Behdadfar L, Daneshpour M, Hedayati M. Microwave Digestion for Urine Iodine Determination . Iranian Journal of Endocrinology and Metabolism 2010; 12 (1) :65-70
URL: http://ijem.sbmu.ac.ir/article-1-777-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 12, Issue 1 (5-2010) Back to browse issues page
مجله ی غدد درون‌ریز و متابولیسم ایران، دو ماهنامه  پژوهشی مرکز تحقیقات غدد درون‌ریز و متابولیسم، Iranian Journal of Endocrinology and Metabolism
Persian site map - English site map - Created in 0.05 seconds with 38 queries by YEKTAWEB 4645